Programs
Employer Branding Student Partner
Quality Control & Analytical Intern
Step 1: Apply for your favorite Internship
After you apply, you will receive an offer letter instantly. No queues, no uncertainty—just a quick start to your career journey.
Step 2: Submit Your Task(s)
You will be assigned weekly tasks to complete. Submit them on time to earn your certificate.
Step 3: Your task(s) will be evaluated
Your tasks will be evaluated by our team. You will receive feedback and suggestions for improvement.
Step 4: Receive your Certificate
Once you complete your tasks, you will receive a certificate of completion. This certificate will be a valuable addition to your resume.
About this Internship
Understand the work of a quality control laboratory in depth: pharmacopoeial standards, specification setting, interpretation of analytical results, analytical method validation, stability studies and out-of-specification investigations. No lab access is needed. All tasks are research-based written documents with calculations done by hand or in a word processor table.
Tasks and Duties
Week 1: Pharmacopoeial Specification Report
Summary
Prepare a complete specification for a finished product from monographs.
Objective
Explain the role of pharmacopoeias in drug quality, describe the Indian Pharmacopoeia, the United States Pharmacopeia and the British Pharmacopoeia in terms of their publishing body, legal status in their region, structure and frequency of update, and explain what happens legally in India when a product does not meet the Indian Pharmacopoeia standard.
Select one commonly used tablet such as paracetamol 500 mg or metformin 500 mg, locate the finished product monograph in at least two pharmacopoeias using library or online access or published summaries, and prepare a complete finished product specification table listing every test, the method reference, the acceptance limit and the frequency, such as release only or release and stability.
For each test on the specification, write an explanation of at least forty words describing what the test measures, how it is performed in principle, which quality defect it detects and what could go wrong in the patient if the product failed that test, covering at least description, identification, assay, dissolution, uniformity of dosage units, related substances and microbial limits.
Conclude with a comparison of the two pharmacopoeial monographs you consulted, noting any differences in tests, methods or limits, explaining why such differences exist and how a company exporting to several countries manages them, then submit the complete report as a 4-5 page Word or PDF document.
Week 2: Analytical Data Interpretation Workbook
Summary
Calculate and interpret assay, dissolution and uniformity results.
Objective
Explain the principle of ultraviolet-visible spectrophotometry and high performance liquid chromatography in simple terms, describe the main components of an HPLC system, and explain the system suitability parameters of retention time, theoretical plates, tailing factor, resolution and relative standard deviation of replicate injections, stating the typical acceptance criteria for each.
Create a fictional but realistic set of HPLC assay data for six samples of a tablet batch including standard and sample weights, dilution volumes, standard purity and peak areas, and calculate the percentage assay for each sample, the mean, the standard deviation and the relative standard deviation, showing every formula and step in tables within your document.
Create fictional dissolution data for twelve tablets at six time points, tabulate the percentage dissolved, calculate the mean and relative standard deviation at each time point, apply the pharmacopoeial acceptance criteria for stage one and stage two testing, and decide whether the batch passes, explaining the staged testing logic clearly.
Create fictional data for the uniformity of dosage units test for ten tablets, calculate the acceptance value using the pharmacopoeial formula with the appropriate constants, decide whether the batch meets the requirement, and write a one-page discussion of the common sources of analytical error in each of these three tests and how an analyst controls them, then submit the complete workbook as a 5-6 page Word or PDF document.
Week 3: Method Validation and Stability Study
Summary
Outline an analytical method validation and design a stability study.
Objective
Explain the purpose of analytical method validation and describe each validation parameter under ICH Q2 including specificity, linearity, range, accuracy, precision at repeatability and intermediate levels, detection limit, quantitation limit and robustness, stating for each parameter how it is tested in practice and the typical acceptance criterion used in the industry.
Prepare a validation protocol outline for an HPLC assay method for your chosen tablet, specifying for each parameter the experiments to be performed, the number of determinations, the concentration levels, the calculations and the acceptance criteria, and create a fictional linearity dataset of five concentrations with peak areas from which you calculate the slope, intercept and correlation coefficient by hand or with a word processor table.
Design a complete stability study for the tablet according to ICH Q1A, specifying the long-term, intermediate and accelerated storage conditions for climatic zone IVb where India is placed, the number of batches, the container closure system, the testing time points, the tests performed at each time point and the significant change criteria.
Create fictional stability data for assay and the main degradation product at zero, three, six, nine, twelve, eighteen and twenty-four months, present the trend, estimate the shelf life by extrapolating to the point where the assay would reach the lower specification limit and explain the limits of such extrapolation, then submit the complete work as a 5-6 page Word or PDF document.
Week 4: Out-of-Specification Investigation
Summary
Conduct a full two-phase investigation of an OOS result.
Objective
Explain the regulatory background of out-of-specification investigations including the United States FDA guidance and the Barr Laboratories court case that shaped it, define the terms out-of-specification, out-of-trend and out-of-expectation, and describe why retesting into compliance is prohibited and how laboratories must handle an unexpected result.
Create a fictional scenario in which the assay of a tablet batch is reported as 88.
2 percent against a specification of 90.
0 to 110.
0 percent, and write a complete Phase I laboratory investigation including the analyst and supervisor checklist, review of the calculation, sample preparation, standard preparation, instrument performance and chromatograms, and the criteria for an assignable laboratory error and for permitted re-measurement or re-preparation.
Assume no laboratory error is found and write the Phase II full-scale investigation covering the review of the batch manufacturing record, the raw material certificates, the in-process controls, the equipment and the environmental conditions, the hypothesis testing with additional sampling under a documented protocol, and the statistical evaluation of all results obtained.
Write the final investigation report with a clear conclusion on whether the original result is valid, the decision on batch disposition, the impact on other batches, and corrective and preventive actions, and add a one-page trend analysis of fictional assay results for twenty previous batches with a simple control chart described in a table, then submit the complete investigation as a 5-6 page Word or PDF document.
Launch Your Internship
Gain real-world skills, work on live projects and get an NSDC-affiliated certificate — absolutely free!